12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
MAX16070/MAX16071
_______________________________________________________________________________________ 5
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 2.8V to 14V, T
A
= -40NC to +85NC, unless otherwise specified. Typical values are at ABP = DBP = V
CC
= 3.3V, T
A
= +25NC.)
(Note 1)
Note 1: Specifications are guaranteed for the stated global conditions, unless otherwise noted. 100% production tested at T
A
=
+25NC and T
A
= +85NC. Specifications at T
A
= -40NC are guaranteed by design.
Note 2: For 3.3V V
CC
applications, connect V
CC
, DBP, and ABP together. For higher supply applications, connect V
CC
only to the
supply rail.
Note 3: Applies to RESET, fault, autoretry, sequence delays, and watchdog timeout.
Note 4: Total unadjusted error is a combination of gain, offset, and quantization error.
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Output Fall Time t
OF
C
BUS
= 10pF to 400pF 250 ns
Data Hold Time t
HD:DAT
From 50% SCL falling to SDA change 0.3 0.9 μs
Pulse Width of Spike Suppressed t
SP
30 ns
JTAG INTERFACE
TDI, TMS, TCK Logic-Low Input
Voltage
V
IL
Input voltage falling 0.8 V
TDI, TMS, TCK Logic-High Input
Voltage
V
IH
Input voltage rising 2 V
TDO Logic-Output Low Voltage V
OL
I
SINK
= 3mA 0.4 V
TDO Logic-Output High Voltage V
OH
I
SOURCE
= 200μA 2.4 V
TDI, TMS Pullup Resistors R
PU
Pullup to DBP 40 50 60 kω
I/O Capacitance C
I/O
5 pF
TCK Clock Period t
1
1000 ns
TCK High/Low Time t
2,
t
3
50 500 ns
TCK to TMS, TDI Setup Time t
4
15 ns
TCK to TMS, TDI Hold Time t
5
10 ns
TCK to TDO Delay t
6
500 ns
TCK to TDO High-Z Delay t
7
500 ns