12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
MAX16070/MAX16071
46 _____________________________________________________________________________________
Register Map (continued)
FLASH
ADDRESS
REGISTER
ADDRESS
READ/
WRITE
DESCRIPTION
254 054 R/W MON5 secondary selectable UV/OV
255 055 R/W MON5 primary OV
256 056 R/W MON5 primary UV
257 057 R/W MON6 secondary selectable UV/OV
258 058 R/W MON6 primary OV
259 059 R/W MON6 primary UV
25A 05A R/W MON7 secondary selectable UV/OV
25B 05B R/W MON7 primary OV
25C 05C R/W MON7 primary UV
25D 05D R/W MON8 secondary selectable UV/OV
25E 05E R/W MON8 primary OV
25F 05F R/W MON8 primary UV
260 060 R/W MON9 secondary selectable UV/OV
261 061 R/W MON9 primary OV
262 062 R/W MON9 primary UV
263 063 R/W MON10 secondary selectable UV/OV
264 064 R/W MON10 primary OV
265 065 R/W MON10 primary UV
266 066 R/W MON11 secondary selectable UV/OV
267 067 R/W MON11 primary OV
268 068 R/W MON11 primary UV
269 069 R/W MON12 secondary selectable UV/OV
26A 06A R/W MON12 primary OV
26B 06B R/W MON12 primary UV
26C 06C R/W Secondary overcurrent threshold
FAULT SETUP
26D 06D R/W Save after EXTFAULT fault control
26E 06E R/W Faults causing store in flash
26F 06F R/W Faults causing store in flash
270 070 R/W Faults causing store in flash
271 071 R/W Faults causing store in flash
272 072 R/W Faults causing store in flash
TIMEOUTS
273 073 R/W
Overcurrent debounce, watchdog mode, secondary threshold type, software
enables
274 074 R/W ADC fault deglitch configuration
275 075 R/W WDI toggle
276 076 R/W Watchdog reset output enable, watchdog timers
277 077 R/W Boot-up delay