4 ______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 2.8V to 14V, T
A
= -40NC to +85NC, unless otherwise specified. Typical values are at ABP = DBP = V
CC
= 3.3V, T
A
= +25NC.)
(Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
OUTPUTS (RESET, GPIO_)
Output-Voltage Low V
OL
I
SINK
= 2mA 0.4
V
I
SINK
= 10mA, GPIO_ only 0.7
V
CC
= 1.2V, I
SINK
= 100μA (RESET only)
0.3
Maximum Output Sink Current
Total current into RESET, GPIO_,
V
CC
= 3.3V
30 mA
Output-Voltage High (Push-Pull) I
SOURCE
= 100μA 2.4 V
Output Leakage (Open Drain) 1 μA
SMBus INTERFACE
Logic-Input Low Voltage V
IL
Input voltage falling 0.8 V
Logic-Input High Voltage V
IH
Input voltage rising 2.0 V
Input Leakage Current IN = GND or V
CC
-1 +1 μA
Output Sink Current V
OL
I
SINK
= 3mA 0.4 V
Input Capacitance C
IN
5 pF
SMBus Timeout t
TIMEOUT
SCL time low for reset 25 35 ms
INPUTS (A0, GPIO_)
Input Logic-Low V
IL
0.8 V
Input Logic-High V
IH
2.0 V
WDI Pulse Width t
WDI
100 ns
MR Pulse Width
t
MR
1 μs
MR to RESET Delay
0.5 μs
MR Glitch Rejection
100 ns
SMBus TIMING
Serial Clock Frequency f
SCL
400 kHz
Bus Free Time Between STOP
and START Condition
t
BUF
1.3 μs
START Condition Setup Time t
SU:STA
0.6 μs
START Condition Hold Time t
HD:STA
0.6 μs
STOP Condition Setup Time t
SU:STO
0.6 μs
Clock Low Period t
LOW
1.3 μs
Clock High Period t
HIGH
0.6 μs
Data Setup Time t
SU:DAT
100 ns