1006C09/01
Analog comparator offset voltage is measured as absolute offset.
Figure 45. Analog Comparator Offset Voltage vs. Common Mode Voltage
Figure 46. Analog Comparator Offset Voltage vs. Common Mode Voltage
0
2
4
6
8
10
12
14
16
18
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
ANALOG COMPARATOR OFFSET VOLTAGE vs.
V = 5V
cc
COMMON MODE VOLTAGE
Common Mode Voltage (V)
Offset Voltage (mV)
T = 85˚C
A
T = 25˚C
A
0
2
4
6
8
10
0 0.5 1 1.5 2 2.5 3
ANALOG COMPARATOR OFFSET VOLTAGE vs.
COMMON MODE VOLTAGE
Common Mode Voltage (V)
Offset Voltage (mV)
V = 2.7V
cc
T = 85˚C
A
T = 25˚C
A