8127B–AVR–08/09
ATtiny4/5/9/10
17.2.11 Current Consumption in Reset and Reset Pulsewidth
Figure 17-51. Reset Supply Current vs. V
CC
(0.1 - 1.0 MHz, excluding Current Through the
Reset Pull-up)
Figure 17-52. Minimum Reset Pulse Width vs. V
CC
RESET SUPPLY CURRENT vs. V
CC
EXCLUDING CURRENT THROUGH THE RESET PULLUP
5.5 V
5.0 V
4.5 V
4.0 V
3.3 V
2.7 V
1.8 V
0
0.01
0.02
0.03
0.04
0.05
0.06
0.07
0.08
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Frequency (MHz)
I
CC
(mA)
MINIMUM RESET PULSE WIDTH vs. V
CC
85 °C
25 °C
-40 °C
0
500
1000
1500
2000
0123456
V
CC
(V)
Pulsewidth (ns)