4
AT24C02A/04A/08A/16A
0976D–12/01
Note: 1. V
IL
min and V
IH
max are reference only and are not tested.
DC Characteristics
Applicable over recommended operating range from: T
AI
= -40°C to +85°C, V
CC
= +1.8V to +5.5V, T
AC
= 0°C to +70°C,
V
CC
= +1.8V to +5.5V (unless otherwise noted).
Symbol Parameter Test Condition Min Typ Max Units
V
CC1
Supply Voltage 1.8 5.5 V
V
CC2
Supply Voltage 2.5 5.5 V
V
CC3
Supply Voltage 2.7 5.5 V
V
CC4
Supply Voltage 4.5 5.5 V
I
CC
Supply Current V
CC
= 5.0V READ at 100 kHz 0.4 1.0 mA
I
CC
Supply Current V
CC
= 5.0V WRITE at 100 kHz 2.0 3.0 mA
I
SB1
Standby Current V
CC
=
1.8V
V
IN
= V
CC
or V
SS
0.6 3.0 µA
I
SB2
Standby Current V
CC
=
2.5V
V
IN
= V
CC
or V
SS
1.4 4.0 µA
I
SB3
Standby Current V
CC
=
2.7V
V
IN
= V
CC
or V
SS
1.6 4.0 µA
I
SB4
Standby Current V
CC
=
5.0V
V
IN
= V
CC
or V
SS
8.0 18.0 µA
I
LI
Input Leakage Current V
IN
= V
CC
or V
SS
0.10 3.0 µA
I
LO
Output Leakage Current V
OUT
= V
CC
or V
SS
0.05 3.0 µA
V
IL
Input Low Level
(1)
-0.6 V
CC
x 0.3 V
V
IH
Input High Level
(1)
V
CC
x 0.7 V
CC
+ 0.5 V
V
OL2
Output Low Level V
CC
=
3.0V
I
OL
= 2.1 mA 0.4 V
V
OL1
Output Low Level V
CC
=
1.8V
I
OL
= 0.15 mA 0.2 V