Rainbow-electronics AT77C105A Manual de usuario Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 39
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
16
AT77C105A [Preliminary]
5419A–BIOM–01/05
Enctrl Register Register Name: Enctrl (7 bits)
Access Type: Read/Write
Function: Interrupts control
CLICKEN: Click interrupts enable
0: default
1: click IRQ enabled
IRQ is generated when a click is detected.
MOVEN: Movement interrupts enable
0: default
1: movement IRQ enabled
IRQ is generated when an X or Y movement is detected.
TRANSITEN: Not used, for testing only
SLICEN: Not used, for testing only
READERREN: Read error interrupts enable
0: default
1: read error IRQ enabled
IRQ is generated when a read error is detected.
Note: The interrupt is cleared after the status register is read.
Heatctrl Register Register Name: Heatctrl (7 bits)
Access Type: Read/Write
Function: Heating control
HEAT: Sensor heating
0: default, no heating
1: heating
The default value is recommended to optimize power consumption.
WDOGEN: Watchdog enable
0: default
b6 b5 b4 b3 b2 b1 b0
CLICKEN MOVEN TRANSITEN SLICEN READERREN
0000000
b6 b5 b4 b3 b2 b1 b0
HEAT WDOGEN HEATV (MSB) HEATV(LSB)
0000000