MAX19516
Dual-Channel, 10-Bit, 100Msps ADC
30 ______________________________________________________________________________________
Integrated Voltage Regulator
The MAX19516 includes an integrated self-sensing lin-
ear voltage regulator on the analog supply (AVDD). See
Figure 17. When the applied voltage on AVDD is below
2V, the voltage regulator is bypassed, and the core
analog circuitry operates from the externally applied
voltage. If the applied voltage on AVDD is higher than
2V, the regulator bypass switches off, and voltage reg-
ulator mode is enabled. When in voltage regulation
mode, the internal-core analog circuitry operates from a
stable 1.8V supply voltage provided by the regulator.
The regulator provides an output voltage of 1.8V over a
2.3V to 3.5V AVDD input-voltage range. Since the
power-supply current is constant over this voltage
range, analog power dissipation is proportional to the
applied voltage.
Power-On and Reset
The user-programmable register default settings and
other factory-programmed settings are stored in non-
volatile memory. Upon device power-up, these values
are loaded into the control registers. This operation
occurs after application of supply voltage to AVDD and
application of an input clock signal. The register values
are retained as long as AVDD is applied. While AVDD is
applied, the registers can be reset, which will overwrite
all user-programmed registers with the default values.
This reset operation can be initiated by software com-
mand through the serial-port interface or by hardware
control using the SPEN and SHDN inputs. The reset
time is proportional to the ADC clock period and
requires 85µs at 100Msps. Table 9 summarizes the
reset methods.
DTIME<2:0> ALLOWED DCLKTIME<2:0> SETTINGS
111 (-3T/16) 111 (-3T/16)
110 (-2T/16) 110 (-2T/16); 111 (-3T/16)
101 (-1T/16) 101 (-1T/16); 110 (-2T/16); 111 (-3T/16)
000 (nominal) 000 (nominal); 101 (-1T/16); 110 (-2T/16); 111 (-3T/16)
001 (+1T/16) 001 (+1T/16); 000 (nominal); 101 (-1T/16); 110 (-2T/16); 111 (-3T/16)
010 (+2T/16) 010 (+2T/16); 001 (+1T/16); 000 (nominal); 101 (-1T/16); 110 (-2T/16); 111 (-3T/16)
011 (+3T/16) 011 (+3T/16); 010 (+2T/16); 001 (+1T/16); 000 (nominal); 101 (-1T/16); 110 (-2T/16); 111 (-3T/16)