LEA-5H,LEA-5S,LEA-5A-DataSheet Preliminary u-bloxproprietary
GPS.G5-MS5-07026-P4
Page 12
your position is our focus
5 Reliability Tests
Testsforproductfamilyqualifications:
Test Standard
Visualinspection
IPC-A-610 “Acceptability of electronic
assemblies”
I.T.R.I.PublicationNo.700
IPC-SM-840BClass2.
Thermalshock -40°C...+125°C,100cycles IEC68-2-14
Functionat
various
temperatures
-40°C/2hours;RT/2hours;
+85°C/2 hours; function tests at stable
temperature
IEC68-2-1andIEC68-2-2
Lifespantest +85°C/1000hours,infunction IEC68-2-2
Dampheat,cyclic +25°C...+55°C;>90%Rh IEC68-2-30
Vibration 10-500Hz;2hours/axis;5g IEC68-2-6
Shock
30g/11ms (halfsine); 3 Shock/axis; no
function
IEC68-2-27
Metallographic
investigations
IPC-QE-650
Table 11: Reliability Tests
Thisspecificationispreliminaryandsubjecttoconfirmation.
6 Design-In
In order to obtain the necessary information to conduct a proper design-in, u-blox strongly recommends
consultingtheLEA-5 Hardware Integration Manual [1].