12
ATF20V8C
0408H–04/01
Notes: 1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
2. All values are at V
CC
and T
A
=25°C.
3. Shaded area indicates preliminary data.
ATF20V8C DC Characteristics
V
CC
= 5.0V and T
A
= 25°C
Symbol Parameter Condition Min Typ Max Units
I
IL
Input or I/O Low
Leakage Current
0 ≤=V
IN
≤=V
IL
(Max) -35 -100 µA
I
IH
Input or I/O High
Leakage Current
3.5 ≤=V
IN
≤=V
CC
10 µA
I
CC
Power Supply
Current, Standby
V
CC
= Max,
V
IN
= Max,
Outputs Open
C-5 Com. 60 90 mA
C-5 Ind. 60 100 mA
C-7 Com. 60 90 mA
C-7 Ind. 60 100 mA
C-10 Com. 60 80 mA
C-10 Ind. 60 90 mA
C-15 Com. 60 80 mA
C-15 Ind. 60 90 mA
I
CC2
Clocked Power
Supply Current
V
CC
= Max,
Outputs Open,
f = 15 MHz
C-5 Com. 70 110 mA
C-5 Ind. 70 125 mA
C-7 Com. 70 110 mA
C-7 Ind. 70 125 mA
C-10 Com. 60 90 mA
C-10 Ind. 60 105 mA
C-15 Com. 60 90 mA
C-15 Ind. 60 105 mA
IOS
(1)
Output Short
Circuit Current
V
OUT
= 0.5V -130 mA
V
IL
Input Low Voltage -0.5 0.8 V
V
IH
Input High Voltage 2.0 V
CC
+ 0.75 V
V
OL
Output Low Voltage
V
IN
= V
IH
or V
IL
,
V
CC
= Min
I
OL
= 24 mA
Com.,
Ind.
0.5 V
I
OL
= 16 mA 0.5 V
V
OH
Output High Voltage V
IN
= V
IH
or V
IL
,
V
CC
= Min
I
OH
= -4.0 mA 2.4 V
Comentarios a estos manuales