7
AT77C104B
5347B–BIOM–08/04
Switching Performances
The following characteristics are applicable to the operating temperature -40° C ≤ Ta ≤ +85° C.
Typical conditions are: nominal value; T
amb
= 25° C; F
SCK
= 12 MHz; duty cycle = 50%; C
LOAD
120 pF in digital output unless
specified otherwise.
Note: 1. T
SCK
= 1/F
CTRL
(clock period)
Note: All power supplies = +3.3V
Note: All power supplies = +2.5V
Table 10. Timings
Parameter Symbol Test Level Min Typ Max Unit
Clock frequency acquisition
mode
F
ACQ
IV 8 16 MHz
Clock frequency navigation
mode and chip control
F
CTRL
I- 0.2MHz
Duty cycle (clock SCK) DC IV 20 50 80 %
Reset setup time T
RSTSU
I½ T
SCK
(1)
ns
Slave select setup time T
SSSU
I½ T
SCK
(1)
ns
Slave select hold time T
SSHD
I½ T
SCK
(1)
ns
Table 11. 3.3V ±10% Power Supply
Parameter Symbol Test Level Min Typ Max Unit
Data in setup time T
SU
IV 3 ns
Data in hold time T
H
IV 1 ns
Data out valid T
V
I30ns
Data out disable time from SS
high
T
DIS
IV 3.8 ns
IRQ hold time T
IRQ
IV 3 µs
Table 12. 2.5V ±5% Power Supply
Parameter Symbol Test Level Min Typ Max Unit
Data in setup time T
SU
IV 3 ns
Data in hold time T
H
IV 1 ns
Data out valid T
V
I30ns
Data out disable time from SS
high
T
DIS
IV 3.8 ns
IRQ hold time T
IRQ
IV 3 µs
Comentarios a estos manuales