MAX7490/MAX7491
Dual Universal Switched-Capacitor Filters
______________________________________________________________________________________ 13
Mode 3
Figure 6 shows the configuration of Mode 3. This mode
is a sampled time (Z transform) equivalent of the classi-
cal 2nd-order state variable filter. In this versatile mode,
the ratio of resistors R2 and R4 can move the center
frequency both above and below the nominal ratio.
Mode 3 is commonly used to make multiple-pole
Chebyshev filters with a single clock frequency. This
mode can also be used to make high-order all-pole
bandpass, lowpass, and highpass filters.
Mode 3 Design Equations
Mode 3A
Figure 7 shows the configuration of Mode 3A. Similar to
Mode 2, this mode adds an external op amp. See
Table 3 for op amp selection ideas. This op amp cre-
ates a highpass notch and lowpass notch by summing
the highpass and lowpass outputs through two external
resistors, R
H
and R
L
. The ratio of resistors R
H
and R
L
adjusts the notch frequency, while R2 and R4 adjust
the bandpass center frequency, since the notch (zero
pair) frequency can be adjusted to both above and
below f
O
. Mode 3A is suitable for both lowpass and
highpass elliptic or Cauer filters. In multipole elliptic fil-
ters, only one external op amp is needed. Use the
inverting input of the internal op amp as the summing
node for all but the final section of the filter.