MAX6775–MAX6781
Low-Power, 1%-Accurate Battery
Monitor in µDFN and SC70 Packages
_______________________________________________________________________________________ 5
Pin Description
µDFN
NAME FUNCTION
11—— — GND2
Reserved. Must be connected to GND. Do not use as the only
GND connection.
2222 2 GND Ground
33—— — LBI
Low-Battery Input. Connect to the resistive divider to set the
trip level.
4444 — LBO
Low-Battery Output, Active-Low. When V
LBI
/V
LBL
falls below
the falling threshold, LBO asserts. LBO deasserts when
V
LBI
/V
LBH
exceeds the rising threshold voltage.
5—5— — N.C. No Connection. Not internally connected.
6565 6 BATT Battery Input. Power supply to the device.
——1 1 — LBH
Rising-Trip-Level Input. Connect to a resistive divider to set the
rising trip level.
——3 3 — LBL
Falling-Trip-Level Input. Connect to a resistive divider to set the
falling trip level.
———— 1 LBI2
Low-Battery Input 2. Connect to a resistive divider to set the
trip level.
———— 3 LBI1
Low-Battery Input 1. Connect to a resistive divider to set the
trip level.
———— 4 LBO1
Low-Battery Output 1, Active-Low. When V
LBI1
falls below the
falling threshold voltage, LBO1 asserts. LBO1 deasserts when
V
LBI1
exceeds the rising threshold voltage. LBO1 is push-pull
on the MAX6781 and open-drain for the MAX6779/MAX6780.
———— 5 LBO2
Low-Battery Output 2, Active-Low. When V
LBI2
falls below the
falling threshold voltage, LBO2 asserts. LBO2 deasserts when
Comentarios a estos manuales