MAX6655/MAX6656
Dual Remote/Local Temperature Sensors and
Four-Channel Voltage Monitors
______________________________________________________________________________________ 15
BIT NAME
POR
STATE
FUNCTION
7 (MSB)
Disable Remote
Temperature 1
Measurement
0 If high, the remote temperature 1 measurement is disabled.
6
Disable Remote
Temperature 2
Measurement
0 If high, the remote temperature 2 measurement is disabled.
5
Disable Internal
Temperature
Measurement
0 If high, the internal temperature measurement is disabled.
4
Disable V
IN3
Measurement
0 If high, the input voltage V
IN3
measurement is disabled.
3
Disable V
IN2
Measurement
0
If high, the input voltage V
IN2
(V
CC
) measurement is disabled for MAX6655
(MAX6656).
2
Disable V
IN1
Measurement
0 If high, the input voltage V
IN1
measurement is disabled.
1
Disable V
CC
Measurement
0
If high, the input voltage V
CC
(V
IN2
) measurement is disabled for MAX6655
(MAX6656).
0 Reserved 0 Reserved for future use.
Table 8. Configuration Byte 2 Bit Assignments
BIT NAME POR STATE FUNCTION
7 (MSB) BUSY 0 ADC is busy converting when high.
6 LHIGH 0
Internal high-temperature ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
5 LLOW 0
Internal low-temperature ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
4 RHIGH 0
External 1 high-temperature ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
3 RLOW 0
External 1 low-temperature ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
2 DODS1 0 A high indicates external diode 1 open/short.
1 R2HIGH 0
External 2 high-temperature ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
0 R2LOW 0
External 2 low-temperature ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
Table 9. Status Byte 1 Bit Assignments