Rainbow-electronics MAX6656 Manual de usuario Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
MAX6655/MAX6656
Dual Remote/Local Temperature Sensors and
Four-Channel Voltage Monitors
14 ______________________________________________________________________________________
REGISTER ADDRESS POR STATE FUNCTION
RV1HL 28h 1101 0011 Read V
IN1
ALERT High Limit
RV1LL 29h 1010 1101 Read V
IN1
ALERT Low Limit
RV2HL 2Ah 1101 0011 Read V
IN2
(V
CC
) ALERT High Limit for MAX6655 (MAX6656)
RV2LL 2Bh 1010 1101 Read V
IN2
(V
CC
) ALERT Low Limit for MAX6655 (MAX6656)
RV3HL 2Ch 1101 0011 Read V
IN3
ALERT High Limit
RV3LL 2Dh 1010 1101 Read V
IN3
ALERT Low Limit
RV0 2Eh 0000 0000 Read V
CC
(V
IN2
) for MAX6655 (MAX6656)
RV1 2Fh 0000 0000 Read V
IN1
RV2 30h 0000 0000 Read V
IN2
(V
CC
) for MAX6655 (MAX6656)
RV3 31h 0000 0000 Read V
IN3
RSL2 32h 0000 0000 Read Status Byte 2
RCL2 33h 0000 0000 Read Configuration Byte 2
WCA2 34h N/A Write Configuration Byte 2
RDID FEh 0000 1010 Read Device ID
RDRV FFh 0100 1101 Read Manufacture ID
Table 6. Command Byte Register Map (continued)
BIT NAME
POR
STATE
FUNCTION
7 (MSB) Mask All 0 Masks out all ALERT interrupts if high.
6 RUN/STOP 0
Standby mode control bit; if high, the device immediately stops converting and
enters standby mode. If low, the device enters normal conversion mode.
5
Mask Remote
Temperature 1
0 High masks out ALERT interrupts due to remote-diode 1.
4
Mask Remote
Temperature 2
0 High masks out ALERT interrupts due to remote-diode 2.
3 Mask V
IN3
0 High masks ALERT interrupts due to V
IN3
.
2 Mask V
IN2
0 High masks ALERT interrupts due to V
IN2
(V
CC
) for MAX6655 (MAX6656).
1 Mask V
IN1
0 High masks ALERT interrupts due to V
IN1
.
0 Mask V
CC
0 High masks ALERT interrupts due to V
CC
(V
IN2
) for MAX6655 (MAX6656).
Table 7. Configuration Byte 1 Bit Assignments
Note 1: Upon application of power, the ADC begins converting. The MSB of the Status Byte register indicates a conversion in
progress. The Status Byte has a value of 80h during conversions and a value of 00h between conversions. Therefore, at power-on,
the Status Byte alternates between 00h and 80h.
Vista de pagina 13