ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.3V, configuration byte register = X8h, T
A
= 0°C to +85°C, unless otherwise noted.)
ELECTRICAL CHARACTERISTICS
(V
CC
= +3.3V, configuration byte register = X8h, T
A
= -55°C to +125°C, unless otherwise noted.) (Note 5)
CONDITIONS
Monotonicity guaranteed
T
R
= +60°C to +100°C
Bits8Temperature Resolution (Note 1)
-3 3
T
R
= -55°C to +125°C
°C
-5 5
Initial Temperature Error,
Remote Diode (Note 2)
V3 5.5Supply-Voltage Range
From stop bit to conversion complete
Autoconvert mode
ms47 62 78Conversion Time
%-25 25Conversion-Rate Timing Error
UNITSMIN TYP MAXPARAMETER
CONDITIONSSYMBOL
ALERT forced to 5.5V
µA
1
ALERT Output High
Leakage Current
ALERT forced to 0.4V
mA
6
ALERT Output Low Sink Current
UNITSMIN TYP MAXPARAMETER
(Note 3) kHz
DC 100
SMBus Clock Frequency
90% to 90% points t
HIGH
µs
4
SMBCLK Clock High Time
10% to 10% points t
LOW
µs4.7SMBCLK Clock Low Time
90% to 10% pointst
F
ns
300
SMBCLK, SMBDATA Fall Time
90% to 90% points
10% to 90% points
t
SU:STA
ns
500
SMBus Repeated Start
Condition Setup Time
µs
4.7
SMBus Start Condition
Setup Time
t
R
µs
1
SMBCLK, SMBDATA Rise Time
pF
5
SMBCLK, SMBDATA Input
Capacitance
90% of SMBCLK to 10% of SMBDATAt
SU:STO
µs
4
SMBus Stop Condition
Setup Time
(Note 4)
10% of SMBDATA to 90% of SMBCLK
t
HD:DAT
µs
0
SMBus Data-Hold Time
90% of SMBDATA to 10% of SMBCLKt
SU:DAT
ns
250
SMBus Data Valid to SMBCLK
Rising-Edge Time
t
HD:STA
µs
4
SMBus Start Condition
Hold Time
Master clocking in data µs
1
SMBCLK Falling Edge to SMBus
Data-Valid Time
Between start/stop condition t
BUF
µs
4.7
SMBus Bus Free Time
V
CC
t
CONV
SYMBOL