Electrical Characteristics The following specifications apply for V
CC
e
5V
DC
unless otherwise specified.
Boldface limits apply from T
MIN
to T
MAX
; all other limits T
A
e
T
j
e
25
§
C. (Continued)
ADC0844BCJ
ADC0844BCN, ADC0844CCN
ADC0844CCJ
ADC0848BCN, ADC0848CCN
ADC0848BCJ
ADC0848BCV, ADC0848CCV
Limit
Parameter Conditions
ADC0848CCJ
Units
Typ
Tested Design
Typ
Tested Design
(Note 5)
Limit Limit
(Note 5)
Limit Limit
(Note 6) (Note 7) (Note 6) (Note 7)
DIGITAL AND DC CHARACTERISTICS (Continued)
I
IN(0)
, Logical ‘‘0’’ Input V
IN
e
0V
b
0.005
b
1
b
0.005
b
1 mA
Current (Max)
V
OUT(1)
, Logical ‘‘1’’ V
CC
e
4.75V
Output Voltage (Min) I
OUT
eb
360 mA 2.4 2.8 2.4 V
I
OUT
eb
10 mA 4.5 4.6 4.5 V
V
OUT(0)
, Logical ‘‘0’’ V
CC
e
4.75V 0.4 0.34 0.4 V
Output Voltage (Max) I
OUT
e
1.6 mA
I
OUT
, TRI-STATE Output V
OUT
e
0V
b
0.01
b
3
b
0.01
b
0.3
b
3 mA
Current (Max) V
OUT
e
5V 0.01 3 0..01 0.3 3 mA
I
SOURCE
, Output Source V
OUT
e
0V
b
14
b
6.5
b
14
b
7.5
b
6.5 mA
Current (Min)
I
SINK
, Output Sink V
OUT
e
V
CC
16 8.0 16 9.0 8.0 mA
Current (Min)
I
CC
, Supply Current (Max) CS
e
1, V
REF
Open 1 2.5 1 2.3 2.5 mA
AC Electrical Characteristics The following specifications apply for V
CC
e
5V
DC
,t
r
e
t
f
e
10 ns unless
otherwise specified. Boldface limits apply from T
MIN
to T
MAX
; all other limits T
A
e
T
j
e
25
§
C.
Tested Design
Parameter Conditions
Typ
Limit Limit Units
(Note 5)
(Note 6) (Note 7)
t
C
, Maximum Conversion Time (See Graph) 30 40 60 ms
t
W(WR)
, Minimum WR Pulse Width (Note 11) 50 150 ns
t
ACC
, Maximum Access Time (Delay from Falling Edge of C
L
e
100 pF 145 225 ns
RD to Output Data Valid) (Note 11)
t
1H
,t
0H
, TRI-STATE Control (Maximum Delay from Rising C
L
e
10 pF, R
L
e
10k 125 200 ns
Edge of RD
to Hi-Z State) (Note 11)
t
WI
,t
RI
, Maximum Delay from Falling Edge of WR or RD to (Note 11) 200 400 ns
Reset of INTR
t
DS
, Minimum Data Set-Up Time (Note 11) 50 100 ns
t
DH
, Minimum Data Hold Time (Note 11) 0 50 ns
C
IN
, Capacitance of Logic Inputs 5 pF
C
OUT
, Capacitance of Logic Outputs 5 pF
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not apply when operating
the device beyond its specified operating conditions.
Note 2: All voltages are measured with respect to the ground pins.
Note 3: When the input voltage (V
IN
) at any pin exceeds the power supply rails (V
IN
k
V
b
or V
IN
l
V
a
) the absolute value of the current at that pin should be
limited to 5 mA or less. The 20 mA package input current limits the number of pins that can exceed the power supply boundaries witha5mAcurrent limit to four.
Note 4: Human body model, 100 pF discharged through a 1.5 kX resistor.
Note 5: Typicals are at 25
§
C and represent most likely parametric norm.
Note 6: Tested limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).
Note 7: Design limits are guaranteed by not 100% tested. These limits are not used to calculate outgoing quality levels.
Note 8: Total unadjusted error includes offset, full-scale, linearity, and multiplexer error.
3