Typical Applications (Continued)
Definition of Terms
Operating Output Voltage: The voltage appearing across
the positive and negative terminals of the device at specified
conditions of operating temperature and current.
Uncalibrated Temperature Error: The error between the
operating output voltage at 10 mV/˚K and case temperature
at specified conditions of current and case temperature.
Calibrated Temperature Error: The error between operat-
ing output voltage and case temperature at 10 mV/˚K over a
temperature range at a specified operating current with the
25˚C error adjusted to zero.
Ground Referred Centigrade Thermometer
DS005698-16
Air Flow Detector
*
DS005698-17
*Self heating is used to detect air flow
LM135/LM235/LM335, LM135A/LM235A/LM335A
www.national.com 12