29
11050A–PMAAC–07-Apr-10
AT73C246
11.4 Power Manager State Description
AT73C246 ICs are available with 2 factory programmed power sequences. The following timing
diagrams refer to “SEQUENCE A” and “SEQUENCE B” programmed ICs as defined in section
17. “Ordering Information” on page 154. See also the structure of register “VERSION (0x7F)”.
11.4.1 POWERDOWN STATE
When AT73C246 is in POWERDOWN state:
• Only V
BACKUP
supply is active. VDD
{0,1,2,3,4}
power supplies are OFF.
• Audio function is OFF.
• ADC function is OFF.
• RSTB pin is held low.
• Led pin is set as input with internal 120k pull-up resistor to VINSYS.
• TWI registers are reset to default value.
When the POWERDOWN state is reached from the RUN state, the CPU power supplies are
switched off sequentially as described in Figure 11-3 on page 30.
WAKEUP0 Pin pulsed to V
BACKUP
Level. Pulse Width. Pin used as WAKEUP event 5 - - ns
WAKEUP1 Pin pulsed to V
PAD
Level. Pulse Width. Pin used as WAKEUP event 5 - - ns
WAKEUP2 Pin pulsed to V
PAD
Level. Pulse Width. Pin used as WAKEUP event 5 - - ns
WAKEUP3 Pin pulsed to V
PAD
Level. Pulse Width. Pin used as WAKEUP event 5 - - ns
Table 11-1. EVENTS Timing Table
Pin Parameter Comments Min Typ Max Units