Battery Commands
Wavecom Battery Charge Management +WBCM
©Restricted
Page: 92 / 158
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 4 August 23, 2007
For <Mode>=3, <ChargeMode>=1:
Action command
AT+WBCM=<Mode>[,[<ChargeInd>][,[<TimeDeltaTempMeas>],
[<BattLevelMax>],[<BattLevelMin>],[<VoltPulseMax>],
[<BatteryTempMaxVolt>,[<BatteryTempMinVolt>],[<Charging_Current>],
[<DedicatedVoltStart>],[<BatteryPulseChargingTimeout>],
[<BatteryFastChargingTimeout>],<WBCITimer>],
[<BattIntRes>,[<BattChangeLevel>]]]
OK
For <Mode>=4:
Action command
AT+WBCM=<Mode>[,<ChargeMode>]
[+WBCM: <Mode>,<ChargeMode>]
OK
For <ChargeMode>=0:
Read command
AT+WBCM?
+WBCM: <Mode>,<ChargeInd>,<BattLevelMax>,<BattLevelMin>,
<TPulseInCharge>,<WBCITimer>,<BattIntRes>,<BattLevelFilter>
OK