Vista de pagina 53
Global Configuration Commands
Report Mobile Equipment Errors +CMEE
©Restricted
Page: 48 / 184
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 1 August 23, 2007
6 Global Configuration Commands
6.1 Report Mobile Equipment Errors +CMEE
6.1.1 Description
This command defines the method for returning error messages. The simple ERROR
message can be replaced by the verbose method to include the results codes +CME
ERROR: <err>. (See section "ME error result code: +CME ERROR" in the "Appendixes"
of the present document for "+CME ERROR" result codes description. See section
"Message service failure result code: +CMS ERROR" in the "Appendixes" of the present
document for "+CMS ERROR" result codes).
6.1.2 Syntax
Action command
AT+CMEE=<n>
OK
Read command
AT+CMEE?
+CMEE: <n>
OK
Test command
AT+CMEE=?
+CMEE: (list of supported <n>s)
OK
6.1.3 Parameters and Defined Values
<n>: error reporting method
0 disable ME error reports, use only "ERROR" (default value)
1 enable "+CME ERROR: <err>" or "+CMS ERROR: <err>"
6.1.4 Parameter Storage
The <n> parameter is stored in EEPROM using AT&W command. The default value
can be restored using AT&F.