MAX7313
16-Port I/O Expander with LED Intensity
Control and Interrupt
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(Typical Operating Circuit, V+ = 2V to 3.6V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at V+ = 3.3V, T
A
= + 25°C.)
(Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
T
A
= +25°C 0.15 0.26
T
A
= -40°C to +85°C 0.3V+ = 2V, I
SINK
= 20mA
T
A
= T
MIN
to T
MAX
0.32
T
A
= +25°C 0.13 0.23
T
A
= -40°C to +85°C 0.26
V+ = 2.5V, I
SINK
= 20mA
T
A
= T
MIN
to T
MAX
0.28
T
A
= +25°C 0.12 0.23
T
A
= -40°C to +85°C 0.24
Output Low Voltage
P0–P15, INT/O16
V
OL
V+ = 3.3V, I
SINK
= 20mA
T
A
= T
MIN
to T
MAX
0.26
V
Output Low-Voltage SDA V
OLSDA
I
SINK
= 6mA 0.4 V
PWM Clock Frequency f
PWM
32 kHz
TIMING CHARACTERISTICS
(Typical Operating Circuit, V+ = 2V to 3.6V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at V+ = 3.3V, T
A
= +25°C.)
(Note 1)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Serial Clock Frequency f
SCL
400 kHz
Bus Free Time Between a STOP and a START
Condition
t
BUF
1.3 µs
Hold Time, Repeated START Condition t
HD
STA
0.6 µs
Repeated START Condition Setup Time t
SU
STA
0.6 µs
STOP Condition Setup Time t
SU
STO
0.6 µs
Data Hold Time t
HD
DAT
(Note 2) 0.9 µs
Data Setup Time t
SU
DAT
180 ns
SCL Clock Low Period t
LOW
1.3 µs
SCL Clock High Period t
HIGH
0.7 µs
Rise Time of Both SDA and SCL Signals, Receiving t
R
(Notes 3, 4)
20 +
0.1C
b
300 ns
Fall Time of Both SDA and SCL Signals, Receiving t
F
(Notes 3, 4)
20 +
0.1C
b
300 ns
Fall Time of SDA Transmitting t
F.TX
(Notes 2, 3, 5)
20 +
0.1C
b
250 ns
Pulse Width of Spike Suppressed t
SP
(Notes 2, 6) 50 ns
Capacitive Load for Each Bus Line C
b
(Notes 2, 3) 400 pF