Eight of the MAX7311’s nine registers are configured to
operate as four register pairs: input ports, output ports,
polarity inversion ports, and configuration ports. After
sending 1 byte of data to one register, the next byte is
sent to the other register in the pair. For example, if the
first byte of data is sent to output port 2, then the next
byte of data is stored in output port 1. An unlimited
number of data bytes can be sent in one write transmis-
sion. This allows each 8-bit register to be updated inde-
pendently of the other registers.
Reading Port Registers
To read the device data, the bus master must first send
the MAX7311 address with the R/W bit set to zero, fol-
lowed by the command byte, which determines which
register is accessed. After a restart, the bus master
must then send the MAX7311 address with the R/W bit
set to 1. Data from the register defined by the com-
mand byte is then sent from the MAX7311 to the master
(Figures 8, 9).
MAX7311
2-Wire-Interfaced 16-Bit I/O Port Expander
with Interrupt
_______________________________________________________________________________________ 9