DS1857
Dual Temperature-Controlled Resistors with
External Temperature Input and Monitors
16 ____________________________________________________________________
MEMORY
LOCATION
(hex)
EEPROM/
SRAM
R/W
DEFAULT
SETTING
(hex)
NAME OF
LOCATION
FUNCTION
80 SRAM R/W Mode
Bit 7 0 X
6——0 X
5——0 X
4——0 X
3——0 X
2——0 X
1——1 TEN
If TEN = 0, the temperature conversions update and the
resistors can be controlled manually. The user sets the
resistor in manual mode by writing to addresses 82h and
83h in Table 01 to control resistors 0 and 1, respectively.
0——1 AEN
AEN = 0 provides manual control of the temperature
index.
81 SRAM R Temp index
This byte is the temperature-calculated index used to
select the address of resistor settings in the look-up
tables.
82
SRAM R/W 00 Resistor 0 Resistor 0 position values from 00h to FFh.
83
SRAM R/W 00 Resistor 1 Resistor 1 position values from 00h to FFh.
84 to 87 SRAM 00 Reserved
88
EEPROM
R/W X X
Bit 7 1 TMP
6——1 V
CC
5——1 MON1
4——1 MON2
3——0 X
2——0 X
1——0 X
0——0 X
89
EEPROM
R/W Configuration
Bit 7 0 X
6——0 X
Table 01h