DS1251/DS1251P
13 of 22
POWER-DOWN/POWER-UP TIMING Over the operating range (3.3V)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
CE at V
IH
before Power-Down
t
PD
0
ms
V
CC
Slew from V
PF(max)
to
V
PF(min)
( CE at V
IH
)
t
F
300
ms
V
CC
Slew from V
PF(max)
to
V
PF(min)
( CE at V
IH
)
t
R
0
ms
CE at V
IH
after Power-Up
t
REC
1.5 2.5 ms
(T
A
= +25°C)
PARAMETER SYMBOL MIN TYP MAX UNITS NOTES
Expected Data Retention Time t
DR
10 years 9
Warning: Under no circumstances are negative undershoots of any amplitude allowed when device is in
battery-backup mode.