Rainbow-electronics DS1807 Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 13
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
DS1807
5 of 13 110499
2-WIRE DATA TRANSFER OVERVIEW Figure 4
Accordingly, the following bus conditions have been defined:
Bus not busy: Both data and clock lines remain HIGH.
Start data transfer: A change in the state of the data line, from HIGH to LOW, while the clock is
HIGH, defines a START condition.
Stop data transfer: A change in the state of the data line, from LOW to HIGH, while the clock line is
HIGH, defines the STOP condition.
Data valid: The state of the data line represents valid data when, after a START condition, the data line
is stable for the duration of the HIGH period of the clock signal. The data on the line must be changed
during the LOW period of the clock signal. There is one clock pulse per bit of data. Figure 4 details how
data transfer is accomplished on the 2-wire bus. Depending upon the state of the R/W bit, two types of
data transfer are possible:
Each data transfer is initiated with a START condition and terminated with a STOP condition. The
number of data bytes transferred between START and STOP conditions is not limited, and is determined
by the master device. The information is transferred byte-wise and each receiver acknowledges with a 9th
bit.
Within the bus specifications a regular mode (100 kHz clock rate) and a fast mode (400 kHz clock rate)
are defined. The DS1807 works in both modes.
Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the
reception of each byte. The master device must generate an extra clock pulse which is associated with this
acknowledge bit.
A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a
way that the SDA line is stable LOW during the HIGH period of the acknowledge related clock pulse. Of
course, setup and hold times must be taken into account. A master must signal an end of data to the slave
by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this case,
the slave must leave the data line HIGH to enable the master to generate the STOP condition.
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 11 12 13

Comentarios a estos manuales

Sin comentarios

Vanco 280715 (100ft wall plate) manuals

Owner’s manuals and user’s guides for Accessories for video Vanco 280715 (100ft wall plate).
We providing 1 pdf manuals Vanco 280715 (100ft wall plate) for download free by document types: User Manual






More products and manuals for Accessories for video Vanco

Models Document Type
280711 (3x1) User Manual   VANCO 280711 (3x1) User Manual, 12 pages
Rapid Link with Surge User Manual   VANCO Rapid Link with Surge User Manual, 2 pages
WMT2337 User Manual   VANCO WMT2337 User Manual, 2 pages
280535 User Manual   VANCO 280535 User Manual, 1 pages
ART4270 User Manual   VANCO ART4270 User Manual, 4 pages
VPW-280759 User Manual   VANCO VPW-280759 User Manual, 32 pages
VPW-280782 (1x2) User Manual   VANCO VPW-280782 (1x2) User Manual, 12 pages
280515 User Manual   VANCO 280515 User Manual, 1 pages
WM3665T User Manual   VANCO WM3665T User Manual, 4 pages
VPW-280709 (8X8) User Manual   VANCO VPW-280709 (8X8) User Manual, 20 pages
280341 User Manual   VANCO 280341 User Manual, 2 pages
VPW-280608 User Manual   VANCO VPW-280608 User Manual, 8 pages
SMA3000 User Manual     VANCO SMA3000 User Manual, 4 pages
WMT2342 User Manual   VANCO WMT2342 User Manual, 2 pages
WM1024 User Manual   VANCO WM1024 User Manual, 4 pages
280702 (1x2) User Manual   VANCO 280702 (1x2) User Manual, 12 pages
WM1024E User Manual   VANCO WM1024E User Manual, 4 pages
VPW-280754 User Manual   VANCO VPW-280754 User Manual, 20 pages
VPW-280781 User Manual   VANCO VPW-280781 User Manual, 8 pages
280531 User Manual   VANCO 280531 User Manual, 1 pages