AMS0805WAH
MOTION SENSOR
13
- Typical Connection with two Slaves
Protocol
The data format is MSB in first and LSB in last.
● Single Byte Write Sequence
● Single Byte Read Sequence
Master Controller
(MCU)
SPI
Serial I/F
Slave Device 1
Slave Device 2
/CS
SCK
MOSI
MISO
/SS
SCK
MOSI
MISO
/SS
SCK
MOSI
MISO
765
4
3
21
0
/SS
SCK
MOSI
MISO
765
4
3
21
0
Commend & Register Byte
MSB LSB MSB LSB
Data Byte
765
4
3
21
0
/SS
SCK
MOSI
MISO 7 6 5
4
3
21
0
Commend & Register Byte
MSB LSB
MSB LSB
Data Byte