ATF16V8C
5
Input Test Waveforms and
Measurement Levels:
t
R
, t
F
< 1.5 ns (10% to 90%)
Output Test Loads:
Note: 1. Typical values for nominal supply voltage. This parameter is only sampled and is not 100% tested.
Power-up Reset
The ATF16V8Cs registers are designed to reset during
power-up. At a point delayed slightly from V
CC
crossing
V
RST
, all registers will be reset to the low state. As a result,
the registered output state will always be high on power-up.
This feature is critical for state machine initialization.
However, due to the asynchronous nature of reset and the
uncertainty of how V
CC
actually rises in the system, the
following conditions are required:
1. The V
CC
rise must be monotonic, from below 0.7V,
2. After reset occurs, all input and feedback setup
times must be met before driving the clock term
high, and
3. The signals from which the clock is derived must
remain stable during t
PR
.
OUTPUT
PIN
5.0V
CL = 50 pF
R1 = 200
R2 = 200
Pin Capacitance
(1)
f = 1 MHz, T = 25°C
Typ Max Units Conditions
C
IN
58pFV
IN
= 0V
C
OUT
68pFV
OUT
= 0V
Parameter Description Typ Max Units
t
PR
Power-up
Reset Time
600 1,000 ns
V
RST
Power-up
Reset Voltage
3.8 4.5 V
Vista de pagina 4