MAX6652
Temperature Sensor and System Monitor
in a 10-Pin µMAX
_______________________________________________________________________________________ 3
Note 1: Total monitoring time includes temperature conversion and four analog input voltage conversions.
Note 2: A master device must provide at least a 300ns hold time for the SDA signal, referred to V
IL
of the SCL signal, to bridge the
undefined region of SCL’s falling edge.
Note 3: C
B
= total capacitance of one bus line in pF. Rise and fall times are measured between 0.3 x V
CC
to 0.7 x V
CC
.
Note 4: Input filters on SDA, SCL, and ADD suppress noise spikes <50ns.
Note 5: Guaranteed but not tested over the entire temperature range.
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
START Condition Hold Time t
HD:STA
0.6 µs
STOP Condition Hold Time t
SU:STO
0.6 µs
Clock Low Period t
LOW
1.3 µs
Clock High Period t
HIGH
0.6 µs
Data Setup Time t
SP:DAT
100 ns
Data Hold Time t
HD:DAT
(Note 2) 0 0.9 µs
Receive SCL/SDA Minimum
Rise Time
t
R
(Note 3)
20 +
0.1C
B
ns
Receive SCL/SDA Maximum
Rise Time
t
R
(Note 3) 300 ns
Receive SCL/SDA Minimum
Fall Time
t
F
(Note 3)
20 +
0.1C
B
ns
Receive SCL/SDA Maximum
Fall Time
t
F
(Note 3) 300 ns
Transmit SDA Fall Time t
F
400pF, I
SINK
= 3mA
20 +
0.1C
B
300 ns
Pulse Width of Spike
Suppressed
t
SP
(Note 4) 50 ns
ELECTRICAL CHARACTERISTICS (continued)
(T
A
= -40°C to +125°C, unless otherwise noted. Typical values are at V
CC
= +5V, T
A
= +25°C.)
Typical Operating Characteristics
(V
CC
= +5V, ADD = GND, ALERT = 10k
to V
CC
, T
A
= +25°C, unless otherwise noted.)
0
100
50
200
150
250
300
2.5 3.5 4.03.0 4.5 5.0 5.5
SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX6652 toc01
SUPPLY VOLTAGE (V)
SUPPLY CURRENT (µA)
A
B
C
D
E
A: T
A
= +125°C
B: T
A
= +85°C
C: T
A
= +25°C
D: T
A
= 0°C
E: T
A
= -40°C
250
225
200
175
150
1 1000
SUPPLY CURRENT
vs. SCL CLOCK FREQUENCY
MAX6652 toc02
CLOCK FREQUENCY (kHz)
SUPPLY CURRENT (µA)
V
CC
= +5V
SCL = 0 to +5V
-5
-2
-3
-4
-1
0
1
2
3
4
5
2.5 3.53.0 4.0 4.5 5.0 5.5
TEMPERATURE ERROR
vs. SUPPLY VOLTAGE
MAX6652 toc03
SUPPLY VOLTAGE (V)
TEMPERATURE ERROR (°C)
T
A
= +85°C
T
A
= 0°C
T
A
= -40°C
Vista de pagina 2