Rainbow-electronics MAX6508 Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
MAX6505–MAX6508
Dual Trip SOT Temperature Switches
4 _______________________________________________________________________________________
Pin Description
PIN
MAX6505 MAX6506 MAX6507 MAX6508
NAME FUNCTION
1- - WARN
Open-Drain Active-Low Warning Output. WARN goes low
when the die temperature exceeds T
WARN
= T
ALARM
-
T
AW.
- 1- - WARN
Push-Pull Active-High Warning Output. WARN goes high
when the die temperature exceeds T
WARN
= T
ALARM
-
T
AW.
2 2 2 2 GND Ground
3, 5 3, 5 - - S1, S0
Delta Temperature Select Input. Connect to V
CC
or GND to
select the difference between T
ALARM
and T
WARN
(Table
1 or see Electrical Characteristics).
- - 33S0
Hysteresis Select Input. Connect to V
CC
for 10°C
hysteresis. Connect to GND for 2°C hysteresis.
4444V
CC
Supply Voltage Input. Bypass V
CC
to GND with a 0.1µF
ceramic capacitor.
- - 5 5 N.C. No Connection. Not internally connected.
- - 6-
OVER
Open-Drain Active-Low Overtemperature Output.
OVER
goes low when the die temperature exceeds the factory-
set value of T
OVER
.
- - _ 6 OVER
Push-Pull Active-High Overtemperature Output. OVER
goes high when the die temperature exceeds the factory-
set value of T
OVER.
- - 1- OK
Open-Drain Active-High Temperature Sensor Output. OK
goes high impedance when the die temperature is
between the factory-set values of T
OVER
and T
UNDER
.
When the die temperature is above T
OVER
or below
T
UNDER
, OK goes low.
- - -
1
OK
Push-Pull Active-Low Temperature Sensor Output. OK
goes low when the die temperature is between the factory-
set values of T
OVER
and T
UNDER
. When the die temp-
erature is above T
OVER
or below T
UNDER
, OK goes high.
6- - - ALARM
Open-Drain Active-Low Alarm Output. ALARM goes low
when the die temperature exceeds the factory-set value of
T
ALARM
.
- 6- - ALARM
Push-Pull Active-High Alarm Output. ALARM goes high
when the die temperature exceeds the factory-set value of
T
ALARM
.
Vista de pagina 3
1 2 3 4 5 6 7 8 9 10 11 12

Comentarios a estos manuales

Sin comentarios