MAX6375–MAX6380
3-Pin, Ultra-Low-Power SC70/SOT23
Voltage Detectors
4 _______________________________________________________________________________________
____________ Applications Information
Interfacing to Different
Logic Voltage Components
The MAX6377/MAX6380 have an active-low, open-
drain output. This output structure will sink current
when OUT is asserted. Connect a pull-up resistor from
OUT to any supply voltage up to 5.50V (Figure 1).
Select a resistor value large enough to allow a valid
logic low (see Electrical Characteristics), and small
enough to register a logic high while supplying all input
current and leakage paths connected to the OUT line.
Negative-Going V
CC
Transients
These devices are relatively immune to short-duration,
negative-going V
CC
transients (glitches). The Typical
Operating Characteristics show the Maximum Transient
Duration vs. Threshold Overdrive graph, for which out-
put pulses are not generated. The graph shows the
maximum pulse width that a negative-going V
CC
tran-
sient may typically have before the devices issue out-
put signals. As the amplitude of the transient increases,
the maximum-allowable pulse width decreases.
Figure 1. Interfacing to Different Logic Voltage Components
Table 1. Factory-Trimmed Reset Thresholds
‡
‡
Factory-trimmed reset thresholds are available in approximately 100mV increments with a 1.5% room-temperature variance.