MAX5512–MAX5515
Dual, Ultra-Low-Power,
8-Bit, Voltage-Output DACs
______________________________________________________________________________________ 15
Table 2. Serial Interface Programming Commands
CONTROL BITS
INPUT DATA
SUB-BITS
C3
C2 C1 C0
D7–D0
S3, S2, S1, S0
FUNCTION
0000 XXXXXXXX 0000 No operation; command is ignored.
0001 8-bit data 0000
Load input register A from shift register; DAC registers unchanged;
DAC outputs unchanged.
0010 8-bit data 0000
Load input register B from shift register; DAC registers unchanged;
DAC outputs unchanged.
0011 ——Command reserved. Do not use.
0100 ——Command reserved. Do not use.
0101 ——Command reserved. Do not use.
0110 ——Command reserved. Do not use.
0111 ——Command reserved. Do not use.
1000 8-bit data 0000
Load DAC registers A and B from respective input registers; DAC
outputs A and B updated; MAX5513/MAX5515 enter normal
operation if in standby or shutdown; MAX5512/MAX5514 enter
normal operation if in shutdown.
1001 8-bit data 0000
Load input register A and DAC register A from shift register; DAC
output A updated; Load DAC register B from input register B; DAC
output B updated; MAX5513/MAX5515 enter normal operation if in
standby or shutdown; MAX5512/MAX5514 enter normal operation
if in shutdown.
1010 8-bit data 0000
Load input register B and DAC register B from shift register; DAC
output B updated; Load DAC register A from input register A; DAC
output A updated; MAX5513/MAX5515 enter normal operation if in
standby or shutdown; MAX5512/MAX5514 enter normal operation
if in shutdown.
1011 ——Command reserved. Do not use.
1100
D7, D6,
XXXXXX
0000
MAX5513/MAX5515 enter standby*, MAX5512/MAX5514 enter
shutdown. For the MAX5513/MAX5515, D7 and D6 configure the
internal reference voltage (Table 3).
1101
D7, D6,
XXXXXX
0000
MAX5512–MAX5515 enter normal operation; DAC outputs reflect
existing contents of DAC registers. For the MAX5513/MAX5515,
D7 and D6 configure the internal reference voltage (Table 3).
1110
D7, D6,
XXXXXX
0000
MAX5512–MAX5515 enter shutdown; DAC outputs set to high
impedance. For the MAX5513/MAX5515, D7 and D6 configure the
internal reference voltage (Table 3).
1111 8-bit data 0000
Load input registers A and B and DAC registers A and B from shift
register; DAC outputs A and B updated; MAX5513/MAX5515 enter
normal operation if in standby or shutdown; MAX5512/MAX5514
enter normal operation if in shutdown.
X = Don’t care.
*Standby mode can be entered from normal operation only. It is not possible to enter standby mode from shutdown.