Rainbow-electronics MAX1855 Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 33
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
MAX1716/MAX1854/MAX1855
High-Speed, Adjustable, Synchronous Step-Down
Controllers with Integrated Voltage Positioning
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(Circuit of Figure 1, V+ = +15V, V
CC
= V
DD
= 5V, SKIP = V
CC
, VPS = PGND, T
A
= 0°C to +85°C, unless otherwise noted. Typical
values are at T
A
= +25°C.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
BIAS AND REFERENCE
Quiescent Supply Current (V
CC
)I
CC
Measured at V
CC
, FB forced above the
regulation point
700 950 µA
Quiescent Supply Current (V
DD
)I
DD
Measured at V
DD
, FB forced above the
regulation point
<1 5 µA
Quiescent Supply Current (V+) I+ 25 40 µA
Shutdown Supply Current (V
CC
) SHDN = GND <1 5 µA
Shutdown Supply Current (V
DD
) SHDN = GND <1 5 µA
Shutdown Supply Current (V+) SHDN = GND, V
CC
= V
DD
= 0 or 5V <1 5 µA
Reference Voltage V
REF
V
CC
= 4.5V to 5.5V, no external REF load 1.98 2 2.02 V
Reference Load Regulation I
REF
= 0 to 50µA 0.01 V
REF Sink Current I
REF
REF in regulation 10 µA
REF Fault Lockout Voltage Falling edge 1.6 V
FAULT PROTECTION
MAX1716 1.8 1.9 2.0
Output Overvoltage Fault
Threshold (Note 5)
Measured at FB
MAX1855 1.97 2.0 2.03
V
Output Overvoltage Fault
Propagation Delay (Note 5)
FB forced to 2% above trip threshold
(MAX1716/MAX1855 only)
1.5 µs
Output Undervoltage Fault
Threshold (Foldback)
35 40 45 %
Output Undervoltage Fault
Propagation Delay
FB forced to 2% below trip threshold 10 µs
Output Undervoltage Fault
Blanking Time (Foldback)
From SHDN signal going high 10 30 ms
Current-Limit Threshold
(Positive, Default)
V
ITH
V
PGND
- V
CS
, ILIM = V
CC
110 120 130 mV
V
ILIM
= 0.5V 40 50 60
Current-Limit Threshold
(Positive, Adjustable)
V
ITH
V
PGND
- V
CS
V
ILIM
= 2V (REF) 170 200 230
mV
Negative Current-Limit
Threshold
V
PGND
- V
CS
-1.2 ×
V
ITH
mV
Zero-Crossing Current-Limit
Threshold
V
PGND
- V
CS
3mV
Thermal Shutdown Threshold Hysteresis = 10°C 150 °C
V
CC
Undervoltage Lockout
Threshold
Rising edge, hysteresis = 20mV, switching
disabled below this level
4.0 4.45 V