less power. SKIP mode allows higher efficiency than
PWM under light-load conditions.
Light-Load Operation in Normal Mode
At light loads, the MAX1765 operates by turning on the
DC-DC converter’s N-channel field-effect transistor
(FET) when V
FB
< V
REF
, synchronized with the rising
edge of the oscillator. The N-channel FET will remain
on, ramping up the inductor current past the minimum
inductor current, until the internal error amplifier and
current mode circuitry determine that the needs of the
system have been met or the device hits the ISET cur-
rent limit. The N-channel is then turned off and the P-
channel is turned on until current decays to the
P-channel turn-off current level. The N-channel will
remain off until V
FB
is again less than V
REF
, and a rising
edge of the oscillator occurs.
MAX1765
800mA, Low-Noise, Step-Up DC-DC Converter
with 500mA Linear Regulator
______________________________________________________________________________________ 11
1.2M H z