MAX1700/MAX1701
1-Cell to 3-Cell, High-Power (1A),
Low-Noise, Step-Up DC-DC Converters
4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(CLK/SEL = ONA = ONB = FB = PGND = GND, OUT = POUT, V
OUT
= 3.6V (Note 6); MAX1701: AIN = LBN = GND, LBP = REF,
T
A
= -40°C to +85°C, unless otherwise noted.) (Note 8)
LBP falling, 15mV hysteresis
Rising V
FB
Adjustable output, CLK/SEL = OUT, V
BATT
= 2.4V,
includes load regulation error for 0A ≤ I
LX
≤ 0.55A
10µA < I
AO
< 100µA
I
AO
= 20µA
V
FB
< 0.1V, CLK/SEL = OUT, V
BATT
= 2.4V, includes load
regulation error for 0A ≤ I
LX
≤ 0.55A
CLK/SEL = OUT
Rising V
OUT
, V
FB
< 0.1V
P-channel
N-channel
V
(Note 4)
V
ONB
= 3.6V
CLK/SEL = GND (MAX1700)
2.92 3.03
CLK/SEL = OUT (MAX1700)
Internal Trip Level
CONDITIONS
mV-5 5LBN, LBP Input Offset
V1.1 1.14External Trip Level
mmho516Transconductance
V1.23 1.27
To maintain input offset < ±5mV (at least one input must
be within this range)
AIN Reference Voltage
mA
250 600
N-Channel Current Limit
1100 1800
V0.5 1.5
LBN, LBP Common Mode
Range
I
REF
= 0 V1.23 1.27Reference Output Voltage
V1.20 1.27FB Regulation Voltage
V3.17 3.38Output Voltage (Note 3)
Ω
0.5
Switch On-Resistance
0.28
0.45
V2.0 2.3
Output Voltage Lockout
Threshold
µA20Supply Current in Shutdown
µA
70
Supply Current in Low-Power
Mode (Note 6)
µA
250
Supply Current in Low-Noise
Mode (Note 6)
UNITSMIN TYP MAXPARAMETER
CLK/SEL = GND (MAX1701)
CLK/SEL = OUT (MAX1701)
CLK/SEL = GND
CLK/SEL = OUT
CLK/SEL = GND
110
300
DC-DC CONVERTER
DC-DC SWITCHES
GAIN BLOCK (MAX1701)
POWER-GOOD (MAX1701)
LOW-BATTERY COMPARATOR (MAX1701)
REFERENCE