Rainbow-electronics MAX1617A Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
0
6
3
9
12
50 5k 500k50k 5M500 50M
TEMPERATURE ERROR vs.
POWER-SUPPLY NOISE FREQUENCY
MAX1617ATOC04
FREQUENCY (Hz)
TEMPERATURE ERROR (°C)
V
IN
= SQUARE WAVE APPLIED TO
V
CC
WITH NO 0.1µF V
CC
CAPACITOR
V
IN
= 250mVp-p
REMOTE DIODE
V
IN
= 250mVp-p
LOCAL DIODE
V
IN
= 100mVp-p
REMOTE DIODE
-20
-10
0
10
20
110303 100
TEMPERATURE ERROR
vs. PC BOARD RESISTANCE
MAX1617ATOC01
LEAKAGE RESISTANCE (M)
TEMPERATURE ERROR (°C)
PATH = DXP TO V
CC
(5V)
PATH = DXP TO GND
-2
-1
0
1
2
-50 50 1000 150
TEMPERATURE ERROR
vs. REMOTE-DIODE TEMPERATURE
MAX1617ATOC02
TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
SAMSUNG KST3904
MOTOROLA MMBT3904
ZETEX FMMT3904
RANDOM
SAMPLES
__________________________________________Typical Operating Characteristics
(T
A
= +25°C, unless otherwise noted.)
MAX1617A
Remote/Local Temperature Sensor
with SMBus Serial Interface
4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.3V, T
A
= -55°C to +125°C, unless otherwise noted.) (Note 6)
Note 1: Guaranteed but not 100% tested.
Note 2: Quantization error is not included in specifications for temperature accuracy. For example, if the MAX1617A device temper-
ature is exactly +66.7°C, the ADC may report +66°C, +67°C, or +68°C (due to the quantization error plus the +1/2°C offset
used for rounding up) and still be within the guaranteed ±1°C error limits for the +60°C to +100°C temperature range
(Table 2).
Note 3: A remote diode is any diode-connected transistor from Table 1. T
R
is the junction temperature of the remote diode. See
Remote Diode Selection
for remote diode forward voltage requirements.
Note 4: The SMBus logic block is a static design that works with clock frequencies down to DC. While slow operation is possible, it
violates the 10kHz minimum clock frequency and SMBus specifications, and may monopolize the bus.
Note 5: Note that a transition must internally provide at least a hold time in order to bridge the undefined region (300ns max) of
SMBCLK’s falling edge.
Note 6: Specifications from -55°C to +125°C are guaranteed by design, not production tested.
CONDITIONS UNITSMIN TYP MAXPARAMETER
STBY, SMBCLK, SMBDATA
2.2
Logic Input High Voltage V
2.4
STBY, SMBCLK, SMBDATA; V
CC
= 3V to 5.5V
V0.8Logic Input Low Voltage
ALERT forced to 5.5V
µA1
ALERT Output High Leakage
Current
Logic inputs forced to V
CC
or GND µA-2 2Logic Input Current
V
CC
= 3V
V
CC
= 5.5V
ALERT, SMBDATA forced to 0.4V
mA6Logic Output Low Sink Current
SMBus INTERFACE
Vista de pagina 3