MAX1227/MAX1229/MAX1231
12-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
_______________________________________________________________________________________ 5
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Externally clocked conversion 208
SCLK Clock Period t
CP
Data I/O 100
ns
SCLK Duty Cycle t
CH
40 60 %
SCLK Fall to DOUT Transition t
DOT
C
LOAD
= 30pF 40 ns
CS Rise to DOUT Disable t
DOD
C
LOAD
= 30pF 40 ns
CS Fall to DOUT Enable t
DOE
C
LOAD
= 30pF 40 ns
DIN to SCLK Rise Setup t
DS
40 ns
SCLK Rise to DIN Hold t
DH
0ns
CS to SCLK Rise Setup t
CSS
40 ns
SCLK Rise to CS Hold t
CSH
0ns
t
CSW
CKSEL = 00, CKSEL = 01 (temp sense) 40 ns
CNVST Pulse Width
CKSEL = 01 (voltage conversion) 1.4 µs
t
T S
Temp sense 55
Voltage conversion 7
CS or CNVST Rise to EOC
Low (Note 9)
Reference power-up 65
µs
TIMING CHARACTERISTICS (Figure 1)
-1.0
-0.4
-0.6
-0.8
-0.2
0
0.2
0.4
0.6
0.8
1.0
0 1024 2048 3072 4096
INTEGRAL NONLINEARITY
vs. OUTPUT CODE
MAX1227/29/31 toc01
OUTPUT CODE
INTEGRAL NONLINEARITY (LSB)
-1.0
-0.4
-0.6
-0.8
-0.2
0
0.2
0.4
0.6
0.8
1.0
0 1024 2048 3072 4096
DIFFERENTIAL NONLINEARITY
vs. OUTPUT CODE
MAX1227/29/31 toc02
OUTPUT CODE
DIFFERENTIAL NONLINEARITY (LSB)
SINAD vs. FREQUENCY
MAX1227/29/31 toc03
FREQUENCY (kHz)
AMPLITUDE (dB)
100101
10
20
40
30
60
50
90
80
70
100
0
0.1 1000
Typical Operating Characteristics
(V
DD
= +3V, V
REF
= +2.5V, f
SCLK
= 4.8MHz, C
LOAD
= 30pF, T
A
= +25°C, unless otherwise noted.)
Note 9: This time is defined as the number of clock cycles needed for conversion multiplied by the clock period. If the internal refer-
ence needs to be powered up, the total time is additive. The internal reference is always used for temperature measure-
ments.