Rainbow-electronics MAX1205 Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
MAX1205
+5V Single-Supply, 1Msps, 14-Bit
Self-Calibrating ADC
4 _______________________________________________________________________________________
C
L
= 20pF
CONDITIONS
ns187 244 301t
CH
Clock High Time
ns488t
CLK
ns4 / f
SAMPLE
t
CONV
Conversion Time
Clock Period
ns16 75t
REL
Bus Relinquish Time
ns16 75t
AC
Data Access Time
ns187 244 301t
CL
Clock Low Time
ns70 150t
OD
Output Delay
ns1 / f
CLK
t
DAV
DAV Pulse Width
ns65 145t
S
CLK-to-DAV Rising Edge
UNITSMIN TYP MAXSYMBOLPARAMETER
DIGITAL INPUTS AND OUTPUTS
(AV
DD
= +5V ±5%, DV
DD
= DRV
DD
= +3.3V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at T
A
= +25°C.)
I
SOURCE
= 200µA
V
IN_
= 0 or DV
DD
CONDITIONS
4Input Capacitance
DV
DD
- 0.8
V
IH
0.8V
IL
Input Low Voltage
Input High Voltage
DV
DD
DV
DD
- 0.4 - 0.03
V
OH
Output High Voltage
0.8CLK
VIL
CLK Input Low Voltage
AV
DD
- 0.8
CLK
VIH
CLK Input High Voltage
9C
CLK
CLK Input Capacitance
±0.1 ±10I
IN_
Digital Input Current
MIN TYP MAX
SYMBOLPARAMETER
-10 ±1 +10I
CLK
Clock Input Current
±0.1 ±10I
LEAKAGE
Three-State Leakage Current
3.5C
OUT
Three-State Output Capacitance
µA
µA
pF
pF
V
V
V
V
V
pF
µA
UNITS
TIMING CHARACTERISTICS
(AV
DD
= +5V ±5%, DV
DD
= DRV
DD
= +3.3V, f
CLK
= 2.048MHz, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical values are at
T
A
= +25°C.) (Note 1)
nst
CLK
/ 2t
ACQ
Acquisition Time
Note 1: Reference inputs driven by operational amplifiers for Kelvin-sensed operation.
Note 2: For unipolar mode, the analog input voltage V
INP
must be within 0V and V
REF
, V
INN
= V
REF
/ 2; where V
REF
= V
RFPS
- V
RFNS
.
For differential mode, the analog inputs INP and INN must be within 0V and V
REF
; where V
REF
= V
RFPS
- V
RFNS
. The com-
mon mode of the inputs INP and INN is V
REF
/ 2.
Note 3: Minimum and maximum parameters are not tested. Guaranteed by design.
Note 4: R
I
varies inversely with sample rate.
Note 5: Calibration remains valid for temperature changes within ±20°C and power-supply variations ±5%.
Note 6: All AC specifications are shown for the differential mode.
ST_CAL = 1, Figure 8
f
CLK
cycles
17,400t
CAL
Calibration Time
I
SINK
= 1.6mA 70 400V
OL
Output Low Voltage mV
Vista de pagina 3